Description
Introduction:
EK-NCM-07S-30A-0CB-1-ST1 is an 7cells battery pack designed in series for battery protection solution by EBAK,
Which use for the application on LiFePO4 base battery packs. this series include 7S 24V 15A/20A/30A/40A/50A/60A/80A/100A/120A/150A/200A/250A bms which is used for 7 series 24V battery pack.
* Monitors temperature, cell voltage, pack voltage, current, state-of-charge, work status
* Over charge protection, over discharge protection, over current protection, short-circuit protection, temperature protection etc.
* Automatic cell-to-cell balance control
* Accurately calculate the capacity and life of the battery
* BMS manufactured by high quality Mos and IC imported
* Use top quality (A-level) protective integrated circuit IC, from the solution of Seiko of Japan.
* Extreme low power consumption. The consumption of the whole device is less than 50uA.
* PCB use high anti-corrosion, high water resistance, high impedance ESD conformal Coating.
* It supports heating function and reserve heating connection interface
EBAK can Customize BMS for Your Lithium Battery Pack
* Custom Any Size: Small, Big, Round, Strip
* Custom Voltage Range: 3V ~ 120V
* Custom Discharge Current: 0.2C ~ 60C (0.1A-200A)
* Custom Communication Protocols: RS232, RS485, EIA-485, CAN Bus , Wireless
* Monitor Battery Status like SOC, SOH
Features:
Provides protection for 7 cells in series
Provides protections during charging and discharging
Low Power Consumption, Designed for over-current and short-circuit protection
Items | Min. | Typ. | Max. | Unit |
Battery Type | Lifepo4 battery | |||
Size | 160X135X10mm | |||
Input Charging Voltage | 29 | 29.4 | 29.8 | V |
Maximum Continuous Charging Current | 10 | A | ||
Maximum Continuous Discharging Current | 30 | A | ||
Operating Temperature | -20 | 25 | 70 | ℃ |
Storage Temperature | -40 | 25 | 85 | ℃ |
Over-Charge Voltage Protection(OVP) | 3.875 | 3.90 | 3.925 | V |
Over-Charge Voltage Protection Release(OVPR) | 3.775 | 3.80 | 3.825 | V |
Over-Charge Protection Delay Time | 0.5 | 1.0 | 1.5 | S |
Over-Discharge Voltage Protection(UVP) | 1.90 | 2.00 | 2.10 | V |
Over-Discharge Voltage Protection Release(UVPR) | 2.40 | 2.50 | 2.60 | V |
Over-Discharge Protection Delay Time | 50 | 100 | 150 | mS |
Over-Current Charge Protection(OCCP1) | – | A | ||
Over-charge-Current Delay Time(OCPCT1) | 4000 | mS | ||
Over-Current Discharge Protection (OCDP1) | 80 | 90 | 100 | A |
Over-discharge-Current Delay Time(OCPDT1) | 175 | 290 | 405 | mS |
Over-Current Discharge Protection Release | Removed the load | |||
Short Circuit Current Protection | 250 | A | ||
Short Circuit Current Protection delay time | 360 | 600 | 840 | цS |
Short Circuit Protection Release | Removed the load | |||
Battery High Temperature Protection | – | 65 | – | ℃ |
Battery High Temperature Protection Release | – | 55 | – | ℃ |
Battery Low Temperature Protection | – | -25 | – | |
Battery Low Temperature Protection Release | – | -15 | – | |
Power MOSFET Temperature Protection | – | 85 | – | ℃ |
Power MOSFET Temperature Protection Release | – | 65 | – | ℃ |
Positive Terminal Temperature Protection | – | 85 | – | ℃ |
Positive Terminal Temperature Protection Release | – | 75 | – | ℃ |
Negative Terminal Temperature Protection | – | 85 | – | ℃ |
Negative Terminal Temperature Protection Release | – | 75 | – | ℃ |
Quiescent Current Under Normal Mode | 130 | цA | ||
Quiescent Current Under UVP Mode | 90 | цA |